Skip to content

Quality & expertise

Test Reports

Independent laboratory reports, each with issuing laboratory, report number, method, sample and date.

T&T Laboratory, Hanoi

Bending Strength & MOE Test — 18 mm, 13-ply (EN 310)

Report 06/MCI.AHK/IV/25 · 11 Sep 2025

Bending strength
49 / 47.3 MPa (two directions, as reported)
Modulus of elasticity
6,470 / 5,670 MPa (as reported)
Test method
EN 310
Sample
18.0 mm, 13 plies, MUF glue

Results refer to the tested sample only (sample purpose: daily testing).

QUATEST 3 — Quality Assurance & Testing Center 3

Anti-slip Property Test — DIN 51130

Report KT3-01466AXD5 · 24 Sep 2025

Acceptance angle (α)
18.0° (average of 2 testers)
Test method
DIN 51130:2014
Sample
Anti-slip film faced plywood, 18 mm

18.0° falls within the R10 band (10°–19°) of DIN 51130. Results refer to the submitted samples only.

T&T Laboratory, Hanoi

Abrasion Resistance Test — EN 438-2

Report 11/MCI.AHV/IV/25 · 13 Sep 2025

Abrasion resistance
680 revolutions (anti-slip surface)
Test method
EN 438-2:2016

Results refer to the tested sample only.

T&T Laboratory, Hanoi

Bending Strength Test — 12 mm, 7-ply (JAS 0233-2)

Report 23/MCI.AHA/I/25 · 26 Mar 2025

Bending strength
50.0 MPa along / 43.5 MPa across
Test method
JAS 0233-2

Kosmex to confirm which current product range this sample represents.

T&T Laboratory, Hanoi (ISO/IEC 17025)

Formaldehyde Emission Test — EN 717-1

Report 005/MC/II/26 · 5 Jun 2026

Formaldehyde emission
0.022 mg/m³ (at 23 °C, 45% RH)
Reference requirement
0.124 mg/m³ (CEN report CR 213)
Test method
EN 717-1, 72 h
Sample
HWPW – VC & UF, 9.0 mm, 5 plies

Results refer to the tested sample only (sample purpose: daily testing).

Request for quotation

Need documents for supplier qualification?

Request TDS, test reports, batch QC records and sourcing documents with your enquiry.

Sales: anna@kosmexgroup.com · +84 399 741 589