Skip to content

Laboratory Test Report

Formaldehyde Emission Test — EN 717-1

Chamber test of formaldehyde emission from a 9 mm, 5-ply hardwood plywood sample (UF glue), to EN 717-1.

Document details
Document typeLaboratory Test Report
StatusDownload PDF
IssuerT&T Laboratory, Hanoi (ISO/IEC 17025)
Reference005/MC/II/26
Applies toPlywood (9 mm, 5-ply sample)
LanguageEnglish
Date / revision5 Jun 2026
Formaldehyde emission0.022 mg/m³ (at 23 °C, 45% RH)
Reference requirement0.124 mg/m³ (CEN report CR 213)
Test methodEN 717-1, 72 h
SampleHWPW – VC & UF, 9.0 mm, 5 plies

Results refer to the tested sample only (sample purpose: daily testing).

Request for quotation

Looking for a reliable plywood supply partner?

Share your requirements with our team and receive product information and a tailored quotation.

Sales: anna@kosmexgroup.com · +84 399 741 589